How To Order from Armstrong Precision Components

1. Select Insert Part Number from list.
2. Add Material Code.
3. Add Finish Code.
4. Add Length (x Length) .

Example 1 : F106CNPX9
M6 x 1.0 x 1.5D Free Running, Cadmium Plated.

F106 : Insert Part Number for M6 x 1.0 Free Running
CN : Stainless Steel to DTD734
P : Cadmium Plated
X9 : 9.0mm Nominal Length (1.5D)

Example 2 : 3591-3CNVX.285
10-32UNF x 1.5D Screw Lock Silver Plated.

3591-3 : Insert Part Number for 10-32UNF Screw Lock
CN : Stainless Steel
V : Silver Plated
X.285 : Nominal Length (1.5D)

Material Codes
CN - Stainless Steel to DTD734
BN - Phosphor Bronze to BS 2873
N90N - Nimonic 90 to BS 2-HR 503
TN - Inconel X750
EN - Nitronic 60
ZN - Zeron 100
GN - Titanium

Finish Codes
None - Natural
P - Cadmium Plated to DTD 904C
V - Silver Plated to DTD 939 / DEF STAN 03-9
Z - Zinc Plated to DTD 903D
W - Dry Film Lube to MIL-L-8937
A - Ion Vapour Deposit (IVD)

Length
ArmaCoil Inserts come in 5 standard lengths based upon the Nominal Diameter e.g. 1D, 1.5D, 2D, 2.5D and 3D.
This length represents the thickness of a plate in which a ArmaCoil will fit and be below the surface both top and bottom. Chamfers and counter bores should be taken into account.
In practice the ArmaCoil is approximately ¾ pitch shorter than the nominal length when fitted.
|